The Controller will need power to work. It has to be touching the drawer bank. Maximum size of the ME Controller multiblock is now configurable. Feed The Beast Wiki. 14 others) automatic. It is the heart of ME Networks and is used to provide more channels to the network. The first step to getting started in AE2 is to acquire Quartz. In that setup each interface was adjacent to at least 3 assemblers, which was the max a Crafting CPU with no co-processors could utilize. You only need 1 cable at the top of the 8 drives in each “block”. In a check board pattern like shown you get 30 interfaces so just one side of a controller. However, you can get around this with controllers. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable. 1. 2. MEチェスト1. Or just do the level emitter thing, or external automated crafters and pre. I opted to use Minetweaker to remove that barrier to entry. or add the modCompileOnly line to your existing dependencies task to your build. The controller can store 16k rf. To do this, however, you need something called channels. Configuration file (ae2ao. 20, AE2 offers an in-game guide. Since Minecraft 1. It’s literally one output for a channel. ) and Energy Units (EU). Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). . That's 32x32 channels (1,024) going through a single dense cable line. Get to know AE2 in a new way! - Download the Minecraft Mod AE2 Additional Opportunity by Domaman202 on Modrinth. 8 channels is always maximum, after that you need a controller. Applied Energisticsについて. you can also use the Cell Workbench to blacklist or whitelist cells to accept or block certain items then use the IO Port to transfer items from the cell to the system. All ME Controller blocks on a ME Network must be connected; else the blocks will turn red. Join. Nope. They only produce 10 AE/t (5 EU/t or 20 RF. It will use only one channel. Not too shabby. I went into a bit more detail a few minutes before you posted your question. I had the exact same chunk loading results. P2P Tunnel. 94. Basic fluix cables have a maximum of 8 channels that can connect in a single branch. 2. 生産 :40AE/t. The Molecular Assembler can connect devices like a basic. The developers of the pack have turned off AE2's channel system, if you'd like to re-enable it, consider the following: Find modpack's files -> Open config folder -> Find "AppliedEnergistics2. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. Featured versions See all [FORGE. it can be hollow, but be careful, some of the outer ones will deactivate, you will have to add holes. The Drawer Controller is a block added by Storage Drawers. Depends on what you're running though. This structure can be built in any cuboid, or size as long as the following Criteria are met. Store high quantity. Each block may have 2 adjacent blocks in at most 1 axis - this is the tricky one. In the network tool GUI of AE2 (access by right clicking an AE2 device on a ME network such as a cable), there is a title "network details", followed by "stored power" (0 RF [0 AE] , as there is no energy cell and I'm powering via tesseract), max power (16 kRF [8 kAE]), then a list of AE2 devices on the network. 12. LP was available very early on and with almost default recipe, was able to do pretty much everything AE2 can (just with a significant speed and size disadvantage), and even had integration with AE2 to make transitioning between them easier (literally a pipe to an ME Interface and the LP system could access the storage of the ME System, so you. This video covers the basic workings of Applied Energistics 2 related to Cables, Channels and Controller. Not sure if this has been done before but this is how I do my molecular assemblers. Join. Most are so small that they don't even have their own Controller, which is called "Ad-Hoc. Il s'agit d'une version nouvelle et améliorée du mod Applied Energistics original. Tunnels are 1 input to N outputs. I have chunk loaders at my Jurassic park and my main base. them outside the network. RS's versions have Stack and Speed Upgrades which both. Der Mod der das möglich macht, nennt sich applied Energistics 2. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. A 3-block controller has 14 faces x 32 channels = 448 total channels. 12. Current versions of OpenComputers add the . Taking this to the max, you can add a Controller and use Dense Cables. Applied Energistics 2. e. ItemMultiMaterial:20. setInterfaceConfiguration ( [slot:number] [, database:address, entry:number [, size:number]]):boolean. Part of a multi-block structure, used to digitally store the blocks within a certain space determined with the use of the Spatial Pylon. Each face can provide up to 32 channels when connected with an ME Dense Covered Cable. Yep, we finish the max size me controller, and get to the draconic staff of power and the philosopher's stone, just for good measure. Even mekanism has a system for it, though in this case its worse than. I was running 64 channels (in p2p) through quantum bridges to each of 5 islands, and about 400 on the main AE island. Every machine in AE2 takes up 1 channel. tterrag1098 • EnderIO/Chisel Dev • 9 yr. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). The item type cap is 61 *per drive*, so once you get 3-4 drives you're pretty much set. ) All Spatial Pylons must be in the outside bounding box. The 1k Storage Cell provides storage for 1024 bytes worth of items, and up to 63 different item types. I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. The center of your ae2 system is typically a structure of me controllers, where each face can give you 32 channels. Cheers!The ME Controller is a block added by the Applied Energistics 2 mod. Alternative, use a level controller pointing to the machine or an export bus/interface with a crafting card set to make the item you want. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. 2 In Conclusion . The mod includes a network-based storage sy. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. Now for the Storage Drawer Solution, you'll need the following for each module: 1 Storage Drawer, 1 ME Storage Bus, 1 Storage Drawers Void Upgrade. Since Minecraft 1. It's the best balance between capacity and storage space. An ME interface allows you to pump things into it. The problem is as of now you can get 2304 channels in a 3x3 with all the centers punched out so it’s hard to beat that. Theinventor10. modsフォルダの中に、ダウンロードした Lazy AE2 を jarファイルのまま コピー&貼り付けする. Controller Network - A network with a Controller. I think this might give more channels per controller (128 per controller vs 124) but I might be wrong. RF等からAEエネルギーへの変換機能を持ち、1面につき32チャンネルを扱える装置。. Thats why you need the cells, they increase your Maximum rf storage, and therefore your maximum possible. Examples of these are enderio, project red, etc. All others (max. I have a large ME controller setup in my primary base, P2P tunnels leading to storage, autocrafting and crafting cpus. It is the main part of any ME Network which handles everything like a CPU does in your computer. The controller is a multiblock structure that follows a few rules: It can be no bigger by 7x7x7; A controller block must not connect to more than 2 other controller blocks on the same axis, or else it will idle; There can only be 1 on the network, or both will idle. com wrote: the existing config works, but i want that it only works with a me controller and the controller i cant find. . A hollow 5x5x5 cube of controllers can provide channels to hundreds of interfaces without a p2p. AE2 network is small, 20 64K drives, 20 ME interfaces and 20 molecular assemblers but no patterns (issue happens with just controller). B:PowerGen=. Surprisingly I can comment on this multiple years later, but thank you. ItemMultiPart:120. Because the ME Controller has a limited surface area, therefore a limited number of channels, u/prozacgod came up with the idea of using a specific shape that has a large surface area that fulfils the maximum size of an ME Controller. Thats: 16 * 1024 * 1024 * 10 * 32 = 5'368'709'120 items per side of an ME controller. Flammable. 7. Got 2 Mekanism ore quadrupling setups but they aren't running constantly. The ME Controller is a block added by Applied Energistics and is the heart of ME Networks. 2 In Conclusion . 1. The CPU must contain at least 1 storage component. You can attach the storage bus to the bottom of the drawer controller. 2. The 1k ME Storage Cell is the first tier of item storage added by Applied Energistics 2. 1. ・まとめ AE2のみでも、各種素材要求物の自動化や実質容量を劇的に増やすこともできる。単体導入や、MODPackに入っていた場合でも安心。 が、強いこだわりや複雑な施設による負荷を避けたいなら、アドオンの「AE2 Stuff」を同時に導入すると、面倒な自動設備を数ブロックに圧縮できるため. About 1/4 machine automation, 1/4 autostocking, and the rest crafting interfaces. Whenever you have more than 8 devices in a network, an ME Contr. Screenshots. It is the new and overhauled version of the original Applied Energistics mod. All controllers on a network must be connected pretty self explanatory. My brother and I completed (up until Avaritia because mindless grind) Enigmatica 2 Expert with just 3 ME Controller blocks, and we had pretty much every machine set up for auto-crafting, and made recipes for anything we would make multiple times. Featured playlist. But depending on the choosen balance between less or more effort the actual amount max might vary between values like 32, 128, 512 or 1024. Top 1% Rank by size . You could have 32 Input P2P tunnels feed into one dense cable and then into one side of a Controller, and the output tunnels will be on the other side of the controller. dman11235 is on the right track, but to expand a bit. Hello, want to know why the MB limit is 17x17x17? This a max amount of 314. 0:00 / 9:22. the network took shows 2. There's three rules with. かまど燃料からAEエネルギーを生成する装置。. Manyullyn 前回宣言した通り、今回からME倉庫の構築を目標として. it's probably because of nested recipes, calculations will take forever to calculate tier 1 essence -> tier 2 -> tier 3 -> tier 4 -> tier 5 -> tier 6 essences needed to craft each tier of seeds. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. 8 in normal cables. . If you want to use storage cells over drawers or barrels, then the Cell Workbench is exactly what you want to be using. I found an old bug report (5 years ago) about me multiblocks chunk loading, so I isolated the controllers. I'm going to try adding another ME Controller to increase the channel limit, but. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. 2. To fix this people build it in a box shape with only the corners of the box, or if you're like me, a line. When your networks starts to grow, so must your ME Controller. wireless. (MAs), and to surround your Interfaces with 6 MAs each (like most AE2 blocks, MAs do transfer channels). The ME P2P Tunnel is a block added by the Applied Energistics mod. Also, AE2 uses priorities intelligently. 5 Some examples of sub-networks and their use . Each device takes one channel. Yes, those conversions are one-way (AE2 is not an open power converter). No, they're saying that you don't need a controller multiblock, which could be 2 controllers or 343 controllers. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). Wiring has its own simple concepts that go along with this channel system: 0. Connections are point-to-point - you can't connect more than 2 blocks together. 2 One route to the controller: 1. That means it could provide a bus for 32 ME drives with 10 16M storage cells each. No idea what you're attempting but from the explanation I don't think it's possible. does ANYONE know why there is no ME controller in the…. AE2 ME Interface → me_interface. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. All the autocrafting bits and bobs are still there and operational. I have a 5x5 big reactor supplying sufficient power. クリスタル成長加速機. 31, no extra mods except client version of lag goggles to debug my base in-case of lag spikes. Yes, an ME Interface can use 6 MAs at the same time without other augments. This means you can output to as many points as you want, but only input at a single point per tunnel. The barrier to entry for AE2 is terrible. 前提MODとして LibNine ・ Applied Energistics 2 を導入する。. 3 3.MEコントローラ、MEチェスト及びMEストレージセルを作る. You can support me and the channel! Read more here: have done videos. Basically the ME Controller and the ME Drives need to be in the same chunk, even if the ME Controller is split between 2 chunks and the cable you are using stays in 1 chunk it will still lag like crazy. The Drawer Controller can coordinate the function of all connected drawers within a 12 block range along any axis. Use quartz to supply power and short-circuit the ME signal (force it to go through the p2p); just go around the p2p with quartz. The island bridges were ~80% full. I like it as it's a challenge. Read below for info and updates on the s. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. so you can go Energy Acceptor (1 channel) -> Main network cable->quartz cable->transport cable. Void junk/non stackable items or store. Simply put, yes. This is mainly done to improve performance because ae2 would have to do a lot of network logic calculation for those connections the way it is coded. If you are using more than maybe 5 controller blocks combined you are doing it wrong (unless it's for aesthetics). You can make that thing look like a tree, with p2ps holding 8 channels each everywhere. Extreme ME Controller with 22 841 channels (Creative AE2 Build) Some time ago I got a request to build an ME Controller with maximum amount of channels possible. One side of the me controller. Manages a single auto crafting task from start to finsh, built of various crafting units. 11. ME Controllers are thus disabled as a result, so anything relating to the. Ah ok, so just a bigger set up I guess. While hovering over an item that has a guide page, hold the W key to open the corresponding guide page. First Appearance : MC 1. Every machine in AE2 takes up 1 channel. #1. Learn P2P Tunnels. ME Controller · ME Power Relay. When I expanded it I searched for a way to have 32 interfaces on one ME Dense Cable. Pick a (big) number, try it. The ME System is used for storing items without using up much physical space. The only ME Controller. the energy acceptor is now passing power to the main network, which is passing it to. 1 AE2AO 8. items in storage drawers and connect the controller to the ME network with a storage bus. The ME Controller's texture will change to display the stored energy level for network use. 12. AE2 Auto-crafting becomes a balancing act between speed and efficiency, while also having to keep channels in mind. As long as all rules are followed and powered, the controller should glow and cycle colors. So within rule 2, there are 6 corner blocks (max 3 connections), 60. I've tried. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. Now you need to get named item 1 into the second inscriber which contains a different name plate press that’ll turn it into named item 2. The default range of a wireless signal is 16 blocks, which can be increased by 2 blocks with a Wireless Booster. An ME controller supports up to 32 channels per block face, but you must use a dense cable to utilize all 32 channels and then branch them off with normal cables as you cannot connect a machine to a dense cable directly. But in Minecraft you need to. MEコントローラ (ME Controller) スカイストーンブロック:4+純粋なフルーシュクリスタル:4+上級プロセッサ:1. 6. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Any data-storing or data-using device needs a channel. Once our network grew to a certain size, with multiple quantum bridges and numerous storage mediums added, we starting having troubles with things disappearing from our ME network. #minecraft #moddedminecraft #appliedenergistics2 toastonrye's AE2 Setpoint Controller, a work in progress!A weekend project I'm probably never going to finis. The dense cable is connected to the controller via p2p interface. ago. That, and the total size of the multiblock can't exceed 7 blocks in any directiob. You can use this to position the contoller in the middle of the P2P cable and get 32 pairs on a dense cable (see the album I posted) or make the P2P system a. Exterior: 578 Tunnels giving 18496 channels. Development. The only catch is that you have to run a separate p2p tunnel to access the auto crafting capabilities. They are capable of transmitting 32 channels, which you can expand. The mod includes a. (3) 5 inscribers. (16x16 area) Describe the feature: +1 range from the controller. Additional channels can be added to network via placing additional controllers adjacent to current controller (with a few structure rules) Dense lines from each side must be completely independent of another, or else the network interferes. Items like the Interface, Import Bus, ME Drive block, etc all consume 1 channel per device. 2Applied Energistics 2. . B:Channels=true. 2; AE2 Version: appliedenergistics2-rv6-stable-6 A futuristic block of chisel has the exact same texture as the AE2 Controller, just use them to make the shape you want and add the controllers you need ^^. Now its working to the maximum potential it has. g. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. A Network requires power, which can be provided by various blocks, and may require ME. MAX_Y, MAX_Z (initially -> 7) - maximum controller size; SCFD (initially -> false) - allows me to make storage cells invulnerable to destruction by fire or lava; External resources. This device also requires a large amount of power to operate. ME Cable can also be colored with dyes. 139. I didn’t use it much, but rushing rf tools storage scanner acts like a ae2 system that uses inventories in the world. This means you can send one kind of power into machines never designed to work with it, which causes major balance issues. Corner blocks and wall edges must be ME Assembler Containment Walls. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. Up to 64 Boosters may be inserted for a total range of 528 block radius and an energy cost of 4. As. jar; Forge Version:14. Now, dense cables are a bit expensive, so you probably don't want them to be wired all over your base. With the network tool you can get the maximum consumption capacity (and current charge). It also has its own power generator in the form of Vibration Chambers. . malicious_bloke. 4 Subordination: Respect My AuthoriTAY . I thought everything was fine. But what is interesting is that the "other side" of the P2P interface is actually managed like a second distinct ME network multiblock. So in my picture you can kinda see a fluix cable running along the bottom of the controllers - this is attached to the controllers with quartz fiber (which allow AE2 power. For convenience, you need to attach a dense cable on each side of a controller except those four that are in the inside circle. Once it's in. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. The AE2 wiki says, the ME Storage Bus needs its own channel. After the move I. Even though it's highly unlikely that anyone would ever use that many machines, I still wanted to see how big I could theoretically make a Network given the logical constraints on the ME Controller. when cheated it on online server or local/single player it acts like a 'stone block' its possible to edit it with the chisel and it becomes another block (like the chisel mod works) Minecraft Version: 1. . Seems weird that it wont try to take a different route that's the same length to the controller. . A basic ME System (without ME Controller) will accept 8 Chanel. I have a question regarding AE2. Its theme is centered around the concept of converting matter into energy and vice versa, to store and transport your items and fluids instantaneously!Your Applied Energistics storage system will probably not work without a ME Controller. Required Tool. RS is far better if you don't want complexity and you aren't building a large system. In practice the amount of channels you actually need comes down to how much you intend to solve with AE2 and the modpack you are playing. r/feedthebeast. AE2 - Device Missing Channel - Have to break ME controller and replace to fix. ME Cable is added by Applied Energistics. Many Pattern Provider as you need to feed your recipes. 4mj/t for a ME drive filled with 64k. . One side of an ME controller can provide a bus for 32 systems. (ME interface, screens, autocrafters, anything) Each side of your ME Controller block has 32 available channels. AE2 current setup. In this video I will give an example of a compact and very competent ME Controller design that can. Join. Ah ok, so just a bigger set up I guess. Side note: this is being done in the mining dimension since server restrictions keep me from doing all this in my main stoneblock base. • 18 days ago. It allows items to be inserted into or extracted from the ME System it is connected to. You might as well just make a converter for whatever systems. AE2 has a 'spatial storage' component. How to make the inscriber, processors, fluix crystals, and complete setup. @Sorbe currently yes. MK234. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. However!At the moment, my ME System is located underneath my Incense Altar Pyramid (Max size), but I am considering moving after I find a new base location. In this episode of Applied Energistics 2, we review how Smart and Dense Cables connect and interact with devices. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. I believe TKH made a controller that gave him 22841 channels at his disposal. As far as I am aware those are the only restrictions. Join. If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. This setup provides 2304 channels (if I calculated it properly), so you can hook up 2304 different devices, such as furnaces or chests, or alloy smelters, sagmills, storage drawers, ME Drives (also part of AE2 - lets you store items digitally)There are two ways. But now whenever I connect the quantum network bridge to my controller it immediately drains it of power and shuts down the entire network. 12. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. 2 始めに. Im happy to present you MyModpackList a site inspired by MyAnimeList and allows you to make your own list of modpacks you want to. The machine requires either a Wooden Crank (placed on top of the block) or power in the form of Redstone Flux (RF), Energy Units (EU), and Teslas (Energy can only be inserted from. The Wireless Booster is an item added by the Applied Energistics 2 mod. 1. 2. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. 0 [1. The cable will also supply every component with energy, if the ME Controller is receiving power. on an inbound basis to power the ME system. Example: I have an ME controller (6 sides). A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. I just use a normal reactor with a huge capacitor bank to store power. Applied Energistics 2's ME Networks require Channels to support devices which use networked storage, or other network services. The "flat controller blocks" are in reality Dense Transformers from the mod Immersive Cables (btw the mod is great, it gives so kuch freedom and clears a lot of wire around). I don't really get this current trend. Top 1% Rank by size . The crafting CPU as a multi-block only requires a single channel for the entire. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is 7x7x7, and that you can only have 3 blocks in a row without an air gap. AppliedEnergistics / Applied-Energistics-2 Public. e. You are correct. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. 3 Dedicated and prioritized external storage with overflow: 2 Inputs and Outputs. An ME System is a system in Applied Energistics 2 that uses a ME Controller and a combination of other items found in Applied Energistics 2. like it doesnt exist. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is. With storage-drawers there is the "drawer controller". 大容量チェストMODとして. Applied Energistics 2 est un mod créé par AlgorithmX2 qui permet de stocker efficacement des objets dans un réseau numérique appelé Matter Energy, ou ME (prononcé Emm-Euh).